Module Type of indicators Color Status Description
- Off The connection between the
storage system and the AS is
abnormal.
Rate indicator of the
FC host port
Green On The transmission rate between
the storage system and the AS
is 4 Gbit/s.
- Off The transmission rate between
the storage system and the AS
is 2 Gbit/s or 1 Gbit/s.
Active indicator of
the mini SAS host
port
Orange Blinking Data is being transmitted.
- Off No data is transmitted.
Link indicator of the
mini SAS host port
Green On The connection between the
storage system and the AS is
normal.
- Off The connection between the
storage system and the AS is
abnormal.
Active indicator of
the iSCSI host port
Orange Blinking Data is being transmitted.
- Off No data is transmitted.
Link indicator of the
iSCSI host port
Green On The connection between the
storage system and the AS is
normal.
- Off The connection between the
storage system and the AS is
abnormal.
Logging In to the ISM
You can query the running status of the ISM and whether an event is generated by logging in to
the ISM.
Clearing an Event According to Advice
When querying the information about the events in the ISM, clear the events according to the
advice.
Locating the Fault Cause
Fault location finds the single cause among all the possible causes through analysis, comparison,
and rule-out.
For details on the methods of locating common faults, see 4.2 Common Methods.
OceanStor S2600 Storage System
Troubleshooting 3 Troubleshooting Process