Parameter Description Value
Interval Time spent waiting of the two
synchronization methods, Timed wait
when synchronization begins and Timed
wait when synchronization ends.
NOTE
This parameter is available when Replication
Mode is set to Asynchronous and
Synchronization Method is set to Timed wait
when synchronization begins or Timed wait
when synchronization ends.
[Value range]
The interval is
an integer
ranging from 1
to 1440
(inclusive),
when minutes is
used as the unit.
The interval is
an integer
ranging from 3
to 59 (inclusive),
when seconds is
used as the unit.
[Default value]
If the unit is
minute, the default
value is 60 minutes.
If the unit is second,
the default value is
30 seconds.
NOTE
When the primary-
end model is 2200
V3, the resource type
is LUN, the unit can
only be minutes and
the interval is an
integer ranging from
15 to 1440
(inclusive).