EasyManua.ls Logo

Huawei OceanStor V3 Series - Page 75

Huawei OceanStor V3 Series
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Description Setting
Interval Waiting time for the two synchronization
methods, Timed wait after
synchronization begins and Timed wait
after synchronization ends.
NOTE
This parameter is available only when
Synchronization Method is set to Timed wait
after synchronization begins or Timed wait
after synchronization ends.
[Value range]
l An integer ranging
from 1 to 1440
(inclusive), when
minutes is used as
the unit.
l An integer ranging
from 3 to 59
(inclusive), when
seconds is used as
the unit.
[Default value]
60, when minutes is
used as the unit.
30, when seconds is
used as the unit.
NOTE
When the primary-end
model is 2200 V3, the
unit can only be
minutes and the
interval is an integer
ranging from 15 to 1440
(inclusive).
Step 5 Select the remote replication pair that you want to add to the consistency group.
1. Click Next, and in Owning Remote Device of Secondary Resource of Pair, select the
remote device.
NOTE
The remote device is the storage device which the secondary resource of the remote replication pair to
be added into the consistency group belongs to.
2. From the Available Remote Replication Pairs list, select one or multiple remote
replication pairs and click
to add.
Step 6 Confirm the consistency group creation.
1. Click Next and view the configuration summary of the consistency group to be created.
2. Click Finish to create the consistency group.
The security alert dialog box is displayed.
3. Read the content in the dialog box carefully, and select I have read and understand the
consequences associated with performing this operation..
4. Click OK.
The Execution Result page is displayed.
5. On Execution Result page, check whether the consistency group is created successfully.
6. Click Close.
----End
OceanStor V3 Series
Remote Replication Feature Guide for Block
3 Configuring Remote Replication
Issue 06 (2018-01-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.