No. Indicator Status (Blinking Fast: On for 0.2s
and then O for 0.2s; Blinking
Slowly: On for 1s and then O for
1s)
Description
Blinking green fast If the alarm/maintenance
indicator is red, an
environmental fault at the DC
side of the solar inverter is
generated.
O The solar inverter disconnects
from all PV strings, or the DC
input voltage of all MPPT
circuits is less than 200 V.
2 Grid connection
indicator
Steady green The solar inverter is in grid-
tied mode.
Blinking green fast If the alarm/maintenance
indicator is red, an
environmental fault at the AC
side of the solar inverter is
generated.
O The solar inverter is not in
grid-tied mode.
3 Communications
indicator
Blinking green fast The solar inverter receives
communication data
normally.
O The solar inverter has not
received communication data
for 10 seconds.
4 Alarm/
Maintenance
indicator
Alarm status Steady red A major alarm is generated.
If the PV connection
indicator or grid
connection indicator is
blinking green fast,
troubleshoot DC or AC
environmental faults as
instructed by the SUN2000
app.
If the PV connection
indicator and grid
connection indicator are
both not blinking green
fast, replace components
or the solar inverter as
instructed by the SUN2000
app.
SUN2000-(100KTL, 110KTL, 125KTL) Series
User Manual 2 Overview
Issue 07 (2020-09-15) Copyright © Huawei Technologies Co., Ltd. 16

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-100KTL Series and is the answer not in the manual?

Huawei SUN2000-100KTL Series Specifications

General IconGeneral
BrandHuawei
ModelSUN2000-100KTL Series
CategoryInverter
LanguageEnglish

Related product manuals