EasyManuals Logo

Huawei SUN2000-20KTL User Manual

Huawei SUN2000-20KTL
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
SUN2000 (8KTL-28KTL)
User Manual
7 LCD
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
LCD
Operation Procedure
6. On the Contrast tab, press and to
set the contrast.
The pages will be displayed in the selected
language.
----End
7.2.6 Setting the Currency and Currency Factor
This topic describes how to set the currency and the revenue per kilowatt hour, which allows
you to calculate the revenue corresponding to the energy yield.
Procedure
The following table describes the procedure for setting the currency and currency factor.
The parameter values in the figures are for reference only.
LCD
Operation Procedure
1. On the default page, press to enter the
main menu.
2. Choose and press .

Table of Contents

Other manuals for Huawei SUN2000-20KTL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-20KTL and is the answer not in the manual?

Huawei SUN2000-20KTL Specifications

General IconGeneral
Max. efficiency98.6%
Rated AC output power20, 000 W
Max. apparent power22, 000 VA
No. of MPP trackers2
Max. input voltage1100 V
Protection degreeIP65
Max. DC Power30, 000 W
Start Voltage200 V
Nominal DC Voltage600 V
Max. Input Current per MPPT26 A
Nominal AC Grid Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading to 0.8 lagging
Total Harmonic Distortion (THD)<3%
DC Reverse-Polarity ProtectionYes
AC Overcurrent ProtectionYes
AC Short-Circuit ProtectionYes
DC Insulation Resistance DetectionYes
Residual Current MonitoringYes
AC Overvoltage ProtectionYes
DC SwitchYes
Cooling MethodNatural Convection
AC output voltage220 V / 380 V, 230 V / 400 V
MPPT operating voltage range200 V - 1000 V
Operating temperature range-25°C to +60°C
Relative Humidity0% - 100%
Operating AltitudeUp to 4000 m
Surge ProtectionType II DC & AC