14
When connecting the shielded cable, choose whether to crimp the OT terminal based on site
requirements.
Tie the communication cables with the cables on internal side of the maintenance compartment.
NOTE
6. Tighten the thread-lock sealing nut and seal the cable gland.
1. Prepare an RJ45 connector.
2. Route the cable through the cable gland.
RJ45 Network Port Connection
No.
Color
Pin Definition
1
White
-and-
orange
RS485A, RS485
differential signal+
2
Orange
RS485B, RS485
differential signal
3
White
-and-green
N/A
4
Blue
RS485A, RS485
differential signal+
5
White
-and-blue
RS485B, RS485
differential signal
6
Green
N/A
7
White
-and-brown
N/A
8
Brown
N/A
3. Insert the RJ45 connector into the RJ45 network
port in the SUN2000 maintenance compartment.
4. Bind the communications cable.

Other manuals for Huawei SUN2000-60KTL-M0