l If the board is still within its startup time, wait until it starts.
l If the board has exceeded its startup time, run the display device command to check the
board status. If the Register field of the board is displayed as Unregistered, go to step 2.
Step 2 Check whether the board was reset.
l Run the display reset-reason [ slot slot-id ] command. If no information about board
resetting is displayed, the board has never been registered. Connect the board to a terminal
with a serial cable and check whether the system software has been loaded to the board
correctly. For details, see Board Software Loading Troubleshooting.
l If information about board resetting is displayed, rectify the fault according to the
instructions in the command output.
If the fault persists, go to step 3.
Step 3 Collect the following information and contact Huawei technical support personnel.
l Results of the preceding troubleshooting procedure
l Configuration file, log file, and alarm file of the AR2200-S
----End
Relevant Alarms and Logs
Relevant Alarms
None.
Relevant Logs
None.