26
9. When should I replace the water lters and the air lters?
Replace the water lter when it is visibly getting darker
in color. Even though the water lter is washable, it can
experience wear and tear overtime. As for the washable air
lter, it is recommended to clean the air lter every 30 days.
However, for heavy users, it may be necessary to clean it more
frequently. Replace the air lter when it becomes worn out.
10. I often hear a squealing noise during the washing cycle, is
it normal?
Yes, it is a normal phenomenon. The pitch uctuations
in ultrasonic sounds can be attributed to various factors,
such as the size and the groove of the record, the water
temperature, and the energy distribution of the transducers�
These uctuations are generally minor and should not have
a signicant impact on the cleaning performance of the
ultrasonic record cleaner�
11. The machine suddenly stops and display a solid yellow
light signal.
The machine automatically stops and alerts with a yellow light
when the thermal sensor detects that the water temperature
in the basin is ≥ 55°C / 131°F. Press the start/pause button to
initiate a 6-minute cool-down cycle� The water will drain out,
and the drying fans will activate for cooling� The cycle will
complete with a blue light signal� If the yellow light persists,
run the cool-down cycle again� Contact support for assistance
if the problem persists�
100 ml
200 ml
300 ml
400 ml
| 38 mm
| 62.5 mm
| 84 mm
| 101 mm
Water level reference chart
12” record label
10” record label
7” record label