UltraScan
®
VIS
Supplemental Manual for EasyMatch
®
QC
Hunter Associates Laboratory
11491 Sunset Hills Road
Reston, Virginia 20190 USA
www.hunterlab.com
A60-1017-658
Manual Version 2.0

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the HunterLab UltraScan VIS and is the answer not in the manual?

HunterLab UltraScan VIS Specifications

General IconGeneral
Wavelength Interval10 nm
Observer Angles2° and 10°
Data InterfaceUSB, RS-232
Measurement Geometryd/8° (diffuse illumination, 8° viewing)
Light SourcePulsed Xenon flash lamp
Measurement Time1 second
Sphere Diameter152 mm (6 inches)
Photometric Range0-200% reflectance
Repeatability±0.01 ΔE*ab for white tile
Inter-Instrument Agreement0.15 ΔE* CIE Lab
Aperture Sizes3 mm, 6 mm, 10 mm
Measurement Area3 mm, 6 mm, 10 mm
Color ScalesCIE L*a*b*, CIE L*C*h°, Hunter Lab, CIE XYZ, Yxy, CIE Yxy
IlluminantsD65, A
Power Supply100-240 VAC, 50/60 Hz
Weight24 lb (10.9 kg)

Summary

UltraScan VIS Features

Reflectance Port

Describes the port at the front of the sensor used for sample placement and measurement.

Transmittance Compartment

Explains the compartment for measuring transmitted color of solids or liquids.

Automated UV Control

Covers Ganz-Griesser calibration using a 400-nm UV filter for fluorescent samples.

UltraScan VIS Installation

Install EasyMatch QC Software

Step-by-step guide to installing the EasyMatch QC software from the CD.

Activate the SoftKey License

Instructions for activating the software license using a Key ID or Key File.

Add the Sensor

Procedure for installing and configuring the UltraScan VIS sensor within the software.

UltraScan VIS Functions

Sensor > Standardize

Explains the process of standardizing the instrument for accurate photometric measurements.

Sensor > UV Filter Calibration

Instructions for calibrating the UV filter for measurements involving fluorescence.

Haze Measurements (Options > Read Method > Haze)

Guides on performing and calculating transmission haze measurements.

UltraScan VIS Maintenance and Testing

Running the Repeatability Test

Procedure to test the instrument's measurement repeatability.

Replacing the Source Lamp

Instructions for replacing the xenon flash lamp module.

UltraScan VIS Specifications

Instrument Performance

Details wavelength range, resolution, accuracy, and repeatability.