Weak Battery
If “jumper cables” are used for emergency starting,
follow this procedure:
Jumper Cables
Connect each end of the RED cable to the •
POSITIVE (+) terminal on each battery, taking
care not to short against chassis.
Connect one end of the BLACK cable to the •
NEGATIVE (-) terminal of the fully charged battery.
Connect the other end of the BLACK cable to a •
good CHASSIS GROUND on the mower with the
discharged battery, away from the fuel tank and
battery.
To remove cables, reverse order
Remove BLACK cable rst from chassis and then •
from the fully charged battery.
Remove RED cable last from both batteries.•
8011-642
Jumper cable connection
IMPORTANT INFORMATION
The mower is equipped with a 12-volt negative
grounded system. The other vehicle must also
be a 12-volt negative grounded system. Do not
use the mower to start other vehicles.
WARNING!
Lead-acid batteries generate
explosive gases. Keep sparks,
ame and smoking materials away
from batteries. Always wear eye
protection when around batteries.