Needle position of zigzag
Check
When the needle (A) swings in maximum zigzag width, the distance between both ends of the needle hole (B) on the
needle plate and the needle drop positions should be equal.
Adjustment
1. Remove the face cover.
2. Set the pattern selector dial to zigzag ”C”and maximun width.
3. Lossen screw A.
4. Adjust needle position by turning screw (B) of zigzag regulator crank:
Clockwise = needle moves right.
Counter-clockwise = needle moves left.
4. Re-check so the distance between both ends of the needle hole on the needle plate and the needle drop positions is
equal
5. Attach the face cover.
( B )
( A )
(A)
(B)