Clearances
Minimum Clearances for Self-Contained cases are to be followed as instructed for proper placement inside store
locations.
- Intake and exhaust clearances are to be a minimum of 8 ft when placed next to a solid wall.
- Height clearance measured from floor follows as a minimum of 10 ft vertically.
- Minimum of 36 in. clearance if near an open aisle is required for proper cycle
ventilation. (Assumed 8 ft clearance from solid wall)
- Case set location to be at least 15ft away from any entrance/exit door
INTAKEVENT
EXHAUSTVENT
EVAPORATOR PAN
Figure1
OBSTRUCTING AIR VENTS WILL AFFECT
CASE PERFORMANCE WHICH COULD
POTENTIALLY LEAD TO CASE FAILURE.