Spec Sheets
SELF-SERVICE DELI REVISION DATE 04/07/21
HUSSMANN – TY(A)3ECRC-5X7I-S SELF-CONTAINED
REFRIGERATION DATA:
CASE LENGTHS CASE USAGE
CONVENTIONAL
CAPACITY ***
(BTU/HR)
AVERAGE DISCHARGE
AIR** (°F) (SEE
SETPOINTS BELOW)
VELOCITY
(FT/MIN)
5X7I DELI TYPE 1 15470 30 ~ 34 125~175
5X7I DELI TYPE 2 16100 30 ~ 34 125~175
**FRONT DISCHARGE AIR MEASURED INSIDE AIR CURTAIN HONEYCOMB
***REFRIGERATION NOTES:
1) CAPACITY FOR REFERENCE ONLY
2) APPROVED UP TO TYPE II CONDITIONS (80°F/55% RH)
3) DEFROST FOR IS BASED ON TERMINATION TEMP, WHICH UNDER
NORMAL CIRCUMSTANCES, IS SHORTER THAN FAILSAFE TIME.
REFRIGERATION DATA CONTINUED:
ELEC. THERMOSTAT / AIR
SENSOR SETTINGS
DEFROST
TYPE
TIME
(MIN)
DEFROST
FREQUENCY
(#/DAY)
TERM.
TEMP
(°F) COI
ONLY
DRIP
TIME
DEFROST WATER
(LBS/DAY/FT)
USAGE
SET
POINT
(°F)
DIFFER-
ENTIAL
(°F)
TYPE 1 24 12 OFF TIME 50
12
46 N/A
12
TYPE 2 24 12 OFF TIME 50
12
46 N/A
14.5
ELECTRICAL DATA:
STANDARD FANS, HEATERS, LED LIGHTS (115 VOLT)
CASE LENGTH
EVAPORATOR FANS
CANOPY LIGHTS
LED
OPTIONAL LED
SHELF LIGHTS
MAX. LED LOAD
(W/ ALL OPTIONS)
ANTI-SWEAT
HEATERS
CONVENIENCE OUTLETS
(OPTIONAL)
# OF
EVAP
FANS
BLADE
DIA. (IN.)
BLADE
PITCH (°)
AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS
#
OUTLETS
VOLTS AMPS
5X7I 6 8 25 1.8 48 0.6 70 0.3 31 0.9 101 0.5 60 1 120 15
CONDENSING UNIT AND EVAPORATIVE PANS
CASE LENGTH
CONDEN SING UNIT EVAP ORATIVE PAN NEMA
PLUG
MOPD (AMPS)
EST. REFG. CHRG.
(LBS)
NOM. HP REFRIG. Hz/Ph Volts RLA VOLTS AMPS WATTS
5X7I 3 R-448A 60 / 1 208 18.0 208 9.6 2000 CS6365C 50 9.0
OPTIONAL HIGH OUTPUT LED LIGHTS (115 VOLT)
CASE LENGTH
CANOPY
LIGHTS
H.O. LED
OPTIONAL SHELF
MAX. H.O. LED
LOAD
AMPS WATTS AMPS WATTS AMPS WATTS
5X7I N/A N/A N/A N/A N/A N/A
8