Entyce Lifting and Transport Instructions
Lift Zones
(CENTERED)
Lift Zones
(CENTERED)
Dollies under
each Base Leg
1. The TY3ECRC is not recommended to be lifted by a forklift due to critical refrigeration components underneath mer-
chandiser. For the safest process defer to using J-Bars
Use of forklift may damage critical refrigeration components
and or drainage piping. Use a spotter when placing forks.
Preferable method of movemnet is to use J-Bars or Jacks.
14
WARNING
2. Remove splash guards and lower body panels before lifting with a jack. Serious damage will occur if the body panels
are not removed (see pg. 13 for body panel removal).
3. The Entyce can be raised at one end to allow the placement of rollers or dollies then repeated to raise opposite end.
4. Never drag or push the Entyce by ANY COMPONENT including ANY GLASS. This will result in damage to the base,
and possibly damage to other components and or injury/serious bodily harm.
7. Evenly support the entire base structure on rollers or dollies before attempting to move. Each Base Leg must have its
own dollie to properly support the case.
8. Smaller dollies (36 in. or less) will require one dollie per corner at all four corners to ensure a safe transporting process
Lifting Instructions