Page 8
Draft Requirements (cont.) The chimney draft depends on the weather conditions.
In stormy weather, you may reduce the chimney draft by closing the damper in the
smoke pipe (if a damper has been installed). If the chimney draft is strong, the combustion
air supply should also be reduced.
Chimney Installation
Do not connect this unit to a chimney flue serving another appliance. Do not
connect to any air distribution duct or system.
HWAM Monet is listed for installation as a vertically top or rear vented wood-burning
stove using a listed class A (UL103HT) for Canada (CAN/ULC-S629) factory built chimney
exiting through the ceiling/attic/roof.
The inside diameter of the chimney, connector pipe must not be smaller than 6" (152
cm) diameter. Single wall 24 gauge MSG (0.58 - 0.71 mm) and adapter must not be
smaller than 6" (152 mm), this may be used in the room where the stove is installed,
follow the chimney manufacturer’s instruction for installation of chimney and chimney
adapter. In Canada, where passage through wall, or partition of combustible construction
is desired, the installation shall conform to CAN/CSA B365.
Factory Built Chimney
When a metal prefabricated chimney is used, the manufacturer’s installation instructions
must be followed. You must also purchase (from the same manufacturer) and install the
ceiling support package or wall pass-through and “T” section package, fire stops (where
needed), insulation shield, roof flashing, chimney cap, etc. Maintain the proper clearance
to the structure as recommended by the manufacturer. The chimney must be the required
height above the roof or other obstructions for safety and proper draft operation.
Masonry Chimney
Ensure that a masonry chimney meets the minimum standards of the National Fire
Protection Association (NFPA) by having it inspected by a professional. Make sure
there are no cracks, loose mortar or other signs of deterioration and blockage. Have
the chimney cleaned before the stove is installed and operated. When connecting the
stove through a combustible wall to a masonry chimney, special methods are needed.
Refer to Combustible Wall Chimney Connector Pass-Throughs on the following pages.