EasyManua.ls Logo

Hy-Security HTG 320-2 - User Manual

Hy-Security HTG 320-2
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Hy
HyHy
Hy-
--
-Security
Security Security
Security
Gate Operators
Gate Operators Gate Operators
Gate Operators
HYDRAULIC
HYDRAULICHYDRAULIC
HYDRAULIC
BARRIER ARM GATE
BARRIER ARM GATEBARRIER ARM GATE
BARRIER ARM GATE
Operators
OperatorsOperators
Operators
With Smart Touch Controller
With Smart Touch ControllerWith Smart Touch Controller
With Smart Touch Controller
Installation and Maintenance Manual
Installation and Maintenance ManualInstallation and Maintenance Manual
Installation and Maintenance Manual
Models HTG 320-2, HTG 320-3
HTG 320-6, HTG 320-8
and
DC Battery UPS version
Revision: ___
Hy-Security Gate Operators
Phone: 1-800-321-9947
FAX: (206) 286-0614
Internet: www.hy-security.com
INSTR# 107
Email: Info@hy-security.com Date 4/01/02

Table of Contents

Questions and Answers

  • A
    Alexander GambleAug 20, 2025
    What to do if the motor is running but the Hy-Security Gate Opener is not moving?
    • W
      williamscassidyAug 21, 2025
      If the motor of your Hy-Security Gate Opener is running but the gate isn't moving, consider the following: 1. Check the manual bypass valve and close it if it's open. 2. If you have a three-phase power supply and the motor is running clockwise, reverse any two of the three lines. 3. Inspect the fluid level in the reservoir. See the maintenance instructions for guidance. 4. If the arm is closed and won't open, try manually lifting it to assist. This could indicate that the open brake valve is set too tight or the pressure relief valve is set too low. 5. If the arm is open and won't close, examine the close brake valve setting.
  • W
    William ConleyAug 31, 2025
    Why does my Hy-Security Gate Opener arm try to close when commanded to open?
    • S
      shannongarciaAug 31, 2025
      If your Hy-Security Gate Opener arm attempts to close when you command it to open, make sure the electrical coil to the hydraulic directional valve is properly connected.
  • D
    Donald SalazarNov 10, 2025
    What to do if my Hy-Security Gate Opener doesn't run when I push the open and close buttons?
    • M
      Michaela BurnsNov 10, 2025
      If your Hy-Security Gate Opener doesn't respond to the open and close buttons, here's what you can check: * First, ensure that the line voltage is present and matches the operator voltage within a 10% range. * Next, verify that control voltage is present at the power supply Common and 24VDC terminals. You might need to reset the circuit breaker (black button) on the transformer. * Confirm that a jumper wire connects Common to Stop, unless you're using an external stop button. * Check the LCD display for any Faults or Errors. * If the gate is open and an open input is active, a close input won't work until the open input is cleared. Check the input status by pressing the LED tact button. Also, voltage drop due to undersized wires can cause the motor contactor to chatter. Refer t...