Installation and Maintenance Manual
25
Description of Functions Available in the Installer Menu
Installer 15 [tC 1] Time clock / Interlock input: This menu item configures the input at terminal #7 to
be either for the gate interlock function or for an external time clock to open input. The default setting is
[tC_1] for the interlock function.
Installer 16 [or 1] OOLD (Outside Obstruction loop detector) function: The default for this menu
item is for full reversal when the OOLD is triggered. The optional setting [or_0] causes the gate to only
pause when triggered. Closure begins as soon as the loop is clear again.
Installer 17 [ir 1] IOLD (Inside Obstruction loop detector) function: The default for this menu item
is for full reversal when the IOLD is triggered. The optional setting [ir_0] causes the gate to only pause
when triggered. Closure begins as soon as the loop is clear again.
Installer 18 [Cr 1] RLD (Reset loop detector) function: The default for this menu item allows the
reset loop detector if triggered to only pause the arm during its closure. The optional setting [Cr_0]
allows the arm to reopen if the reset loop detector is triggered during closure of the gate.
Installer 19 [Cb 0] RLD (Reset loop detector) function: The optional setting for this menu item allows
an RLD input to disable the free exit detector (ELD) until the gate is fully closed. This is used for bi-
directional traffic. The default function allows normal operation of the free exit detector.
Installer 20 [CP 0] RLD (Reset loop detector) function: The default for this menu item allows the
reset loop detector, when triggered and released, to close the arm immediately. The optional setting
[Cp_1] allows the Smart Touch system to remember an additional open count if the open input is
activated a 2
nd
time while the first vehicle still remains over the reset loop. This option is needed when
there is an anti-pass back type card reader to prevent a vehicle from being stranded.
Installer 21 [Eb 0] ELD (Free exit loop detector) function: The optional setting for this menu item
creates an automatic close function if a vehicle triggers, than backs off the free exit loop detector. The
default function allows normal latch open operation of the free exit detector.
Installer 22, 23, 24 [r1 0], [r2 0], [r3 0] User output relay 1 - 3 programming options: These three
menu items are used to configure the function of the three user output relays. There are 19 optional
choices, which are described in detail on page 26.
Installer 25 [t L 0] Gate Open alert: This menu item is to adjust the time delay before activating the
user relay function #8, described on page 26. Time settings up to 135 seconds.
Installer 26 [Lt 0] Loitering alert: This menu item is to adjust the time delay before activating the user
relay function #13, described on page 26. Time settings up to 135 seconds.
Installer 27 [ELd0] Factory ELD: Controls the HY-5A Free Exit loop detector, see page 39.
Installer 28 [iLd0] Factory IOLD: Controls the HY-5A IOLD loop detector, see page 39.
Installer 29 [oLd0] Factory OOLD: Controls the HY-5A OOLD loop detector, see page 39.
Installer 30 [rLd0] Factory RLD: Controls the HY-5A Reset loop detector, see page 39.