FAM 15/30/50/70 Troubleshooting
HYDAC Filter Systems GmbH
en
Page 52 / 68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06
Float switch
Step
Description
Malfunction:
"Float switch"
1. Empty oil pan
2. Press RESET key
3. Start FAM
4. Carry out leakage check, remedy leakages
5. Does malfunction reappear after ≈ 2 seconds?
->a. Yes -> proceed to Step 7.
6.
->b. No -> proceed to Step 8.
7. Check float switch and supply lines
8. The failure is repaired.