FAM 15/30/50/70 Troubleshooting
HYDAC Filter Systems GmbH
en
Page 56 / 68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06
Outlet (OUT) clogged
Step
Description
1. Fault:
"Outlet clogged"
Cause: Medium cannot flow out of the vacuum chamber (emptying
pump pressure limit = 5 bar)
2. Check locking features in the return-flow line. Open if blocked.
3. To reset the failure, press the RESET key
4. Does malfunction reappear after 4 minutes?
->a. Yes -> proceed to Step 6.
5.
->b. No -> proceed to Step 7.
6. Check the pressure relief valve of the evacuation pump for proper
functioning.
7. The failure is repaired.