FAM 15/30/50/70 Troubleshooting
HYDAC Filter Systems GmbH
en
Page 58 / 68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc 2008-10-06
Overflow V-pump
Step
Description
1. Fault:
"V-pump overflow"
2. Cause: fill level in the vacuum pump is too high
3. Water Ring Vacuum Pump:
- Water does not flow into the condensation tank
- Check drain valve and clean if necessary
- Check functioning of float switch
Rotary vane vacuum pump:
- Drain oil until the level is between Min. and Max.
4. To reset the failure, press the RESET key
5. The fault recurs?
->a. Yes -> proceed to Step 7.
6.
->b. No -> proceed to Step 8.
7. Check SPS for proper
functioningThere may be too much
foam in the vacuum chamber ->
Reduce the vacuum
-> proceed to Step 4.
8. The failure is repaired.