HydraFacial Handpiece
The HydraFacial
handpiece tubing chambers must be cleaned and disinfected using the cleaning brush.
1. Make sure ow control is fully open. Detach the handpiece from all tubing. Gently twist the knobs counter-clockwise to detach
each tube from the handpiece.
2. Insert the cleaning brush into the vacuum (smaller opening) on the face of the handpiece Push it in gently all the way, while
rotating in either direction. Repeat with the opening on the back with the blue twist lock connector.
Vacuum
opening
Face of the handpiece
Note: Barbicide is a recommended
disinfectant (follow Barbicide's
iInstructions for use). Isopropyl
alcoholis not suitable as a disinfectant.
3. Wash the brush bristles in soapy water between each handpiece opening insertion to clean off debris.
4. When the brush cleaning is completed, make sure all the blue toggle switches are in the 'OFF' position. Turn the grey 'SYSTEM
RINSE' toggle switch up to the 'ON' position and set the vacuum setting to 26. Press on the cleaning cap and ush through the
handpiece and tubing for 1 minute.
5. Use one Barbicide wipe to clean the entire outer surface of the Handpiece, removing all visible soil. Use a second Barbicide
wipe to thoroughly wet the surface of the Handpiece and ensure the Handpiece remains visibly wet for 2 minutes.
Waste Canister
After Each Service
1. Empty waste on the back of the unit. DO NOT let the waste canister ll above 450 mL.
Daily
1. Wash and wipe/spray germacide over waste canister and lid.
Note: Always remove the waste canister before transporting the unit.
Touchscreen
As Needed
The surface of touchscreen may be cleaned as needed to remove any residue or dust.
1. Apply window or glass cleaner on a non-scratching microber cloth and wipe the touchscreen. Do not apply the cleaner directly
on the touchscreen. Avoid getting liquids inside the touchscreen.
Note: Do not use any type of alcohol or strong solvent, as well as thinner, benzene, abrasive cleaners, or compressed air,
as it may damage the touchscreen surface.
Removable Front Door
As Needed
The surface of removable front door may be cleaned as needed.
1. Apply any plastic cleaner (available at your nearest hardware store, i.e., Novus Plastic Clean & Shine) and use a non-scratching
cloth or paper towel to wipe it clean. Do not use any type of alcohol or any strong solvent.
Skin Imaging Camera (Sold separately.)
1. Clean the chin rest with an alcohol wipe after each use.