152 HyPrecision Predictive waterjet pump Operator Manual 810120
7 – Troubleshooting
Troubleshooting
Normal status
Pump starting
Refer to Start the pump on page 61 for information about the start sequence.
Pump on
Alarms
The controller monitors the pump while the pump is operating. When the controller senses a problem that is likely
to cause damage to the equipment, the operator interface shows an Alarms screen and the beacon light flashes.
Operator interface Beacon light Intensifier Primary motor
Primary operation screen
with the start sequence
progress bar
Green, flashing Enabled On
Operator interface Beacon light Intensifier Primary motor
Primary operation screen Green, not flashing Enabled On
Operator
interface
Beacon light Intensifier Primary motor Cause
Warning
Amber, flashing Enabled On
The controller senses
a condition that can
cause a problem or a
failure.
Fault 1
Red, flashing Off
On, pump is in
cooling mode
The controller senses
a condition that will
cause a problem or a
failure.
Fault 2
Red, flashing Off Off
The controller senses
a failure condition.
Fault 3
Red, flashing Enabled On
The Seal Maintenance
Indicator (SMI)
senses a seal failure
condition.