Echion™
Operator Manual
810770 – REVISION 3
ENGLISH

Table of Contents

Questions and Answers

  • E
    Elizabeth SullivanAug 19, 2025
    What to do if the Hypertherm Water Pump shows Fault 1: Low Inlet Water Pressure?
    • A
      Amanda CummingsAug 19, 2025
      If the supply-water pressure is lower than 2.8 bar (280 kPa / 40 psi), increase the supply pressure. If pressure is lost because of a leak, identify the source of a leak and correct the problem. If the supply water is off, turn it on.
  • J
    Jonathon JenkinsAug 21, 2025
    What to do if Hypertherm Echion Water Pump shows Fault 2: Hydraulic Fluid Level is Low?
    • I
      Ian HarrisAug 21, 2025
      If the tank is full, replace the sensor. If a hydraulic fitting or a hydraulic hose is leaking, fix the leak. If the float switch in the hydraulic fluid tank monitors the fluid level, fix the leak. Check the low-pressure poppet if a poppet (high-pressure or low-pressure) is stuck or leaking.
  • V
    Veronica BradleyAug 23, 2025
    What to do if Hypertherm Water Pump shows Fault 2: Primary Motor?
    • N
      Nathaniel JoyceAug 23, 2025
      If the primary motor did not start, reset the relay. The relay can take several minutes to cool before resetting. If the motor is too hot, refer to Primary motor on page 117. If the soft starter sensed a fault, turn the primary breaker disconnect lever on the electrical enclosure door to OFF, then turn the primary breaker disconnect lever on the electrical enclosure door to ON. It can take several minutes for the system to reboot. If a fuse in the electrical enclosure has blown, replace the blown fuse.
  • A
    Aaron JonesAug 26, 2025
    What to do if Hypertherm Echion Water Pump displays Warning: Boost Motor Warning: Fan Motor On?
    • M
      Matthew FlynnAug 26, 2025
      If the boost motor or the fan motor did not start because the thermal overload relay has tripped, reset the relay. Find the thermal overload relay on the motor starter. Turn the knob clockwise to the ON position (I). Release the knob. It snaps counterclockwise to the OFF position (O). Turn the knob clockwise to the ON position (I) again.
  • M
    Maria AdkinsAug 27, 2025
    Why is the Hypertherm Water Pump motor too hot?
    • C
      Carol AliAug 27, 2025
      If the motor is not cooling sufficiently, clean the air inlet. If the motor is being started too frequently, wait longer between stopping and starting the motor. If the motor bearing is too hot, lubricate the bearing.
  • W
    whoffmanAug 30, 2025
    What causes Fault 1: Intensifier Overstroke in Hypertherm Water Pump?
    • J
      johnsonsusanAug 30, 2025
      If an overstroke fault occurs when the hydraulic piston travels faster than the pump can sustain, check the low-pressure poppet on the same side as the overstroke and the high-pressure poppet on the opposite end from the overstroke.
  • L
    Laura WilsonSep 1, 2025
    What to do if Hypertherm Water Pump displays Warning: Start Procedure Hydraulics?
    • A
      angelamartinezSep 1, 2025
      If the cutting head is on, make sure that the cutting head is off. If the bleed-down valve is leaking, repair or replace the bleed-down valve. If the bleed-down valve is not receiving air, make sure that the compressed air supply is on. If the Hydraulics timer setting is too short, adjust the timer on the Start-procedure Timers screen.
  • S
    Shannon WalshSep 2, 2025
    Why the intensifier does not stroke in Hypertherm Echion Water Pump?
    • D
      David BlackwellSep 3, 2025
      If the intensifier does not stroke because the intensifier control is off, turn intensifier control on. If the cutting head is off, turn on the cutting head. If a proximity switch has failed, replace the switch.
  • A
    Amy GriffinSep 4, 2025
    Why is Hypertherm Echion leaking water from the intensifier?
    • J
      jeffreyedwardsSep 4, 2025
      If water leaks from the intensifier because a high-pressure water seal is damaged, replace the high-pressure seal.
  • K
    Kristin MillerSep 6, 2025
    What to do if Hypertherm Water Pump shows Fault 2: Water Pressure Control Error?
    • G
      Gregory HendersonSep 7, 2025
      If the pump did not get to the target water pressure within the expected time, replace the component. If the hydraulic pressure transducer on the pump manifold has failed, replace the component. If the proportional valve has failed or the proportional valve coil has failed, replace the component. If the hydraulic pump has failed, replace the component. If the orifice has failed, check the condition of the orifice. Replace it, if necessary.

Summary

Warranty

Waterjet product warranty

Details warranty coverage and exclusions for Hypertherm waterjet products.

Disclaimer

States that manual information is believed reliable but may contain errors.

Product stewardship

National and local safety regulations

Safety regulations take precedence over manual instructions; compliance is required.

Certification test marks

Identifies certified products and their conformance to national safety standards.

Environmental stewardship

Chemical handling and usage

Provides information on Material Safety Data Sheets (MSDS) and Safety Data Sheets (SDS).

Safety

User qualification and training

Outlines necessary training for users operating or maintaining the equipment.

Emergency medical information and treatment

Provides critical medical guidance for high-pressure waterjet injuries.

Safety information for operation, maintenance, repair, and installation

Lists essential safety precautions for various operational aspects of the equipment.

Symbols and marks

Information and symbols

Defines safety symbols like DANGER, WARNING, CAUTION, and NOTICE.

Symbols and marks found on the equipment

Lists and explains symbols and marks typically found on Hypertherm equipment.

Optional equipment

Boost pump

Explains the function of a boost pump to increase water pressure.

Operation

About the controls

Describes the operation panel controls including buttons, key switches, and indicator lights.

Operator interface

Introduces the primary operation screen and its functions.

Turn on the pump: beginning of day

Provides a step-by-step procedure for daily pump startup and inspection.

Check the hydraulic fluid

Details how to check the hydraulic fluid level and quality.

Start the pump

Guides the user through the process of starting the pump.

Operate the pump

Covers selecting pressure modes and setting target water pressure.

Stop the pump

Describes procedures for stopping the pump remotely and locally.

Emergency stop

Explains the function and use of the emergency stop button.

Preventive maintenance

Safety

Lists safety precautions specific to performing preventive maintenance.

Preventive maintenance schedule

Provides a recommended schedule for maintenance tasks based on operating hours.

Intensifier

Details maintenance tasks for the intensifier, including repair intervals and procedures.

Replace the water filter

Details the procedure for replacing the water filter based on usage or pressure differential.

Test the water quality

Guides the user through testing pH, silica content, water hardness, and TDS.

Replace the hydraulic fluid

Details the procedure for replacing the hydraulic fluid based on time or condition.

Lubricate the primary motor bearings

Describes the process for lubricating the primary motor bearings every 3,000 hours.

Postmaintenance start procedure

Guides the user through a gradual startup procedure after significant maintenance.

Parts lists

Tools

Lists the standard tool kit and its components required for maintenance.

Maintenance and repair kits

Lists available kits for maintaining and repairing the pump.

High-pressure water system

Lists components of the high-pressure water system with part numbers.

Low-pressure water system

Lists components of the low-pressure water system with part numbers.

Troubleshooting

Safety

Safety precautions to follow during troubleshooting activities.

Alarms

Describes how the controller indicates problems and how to acknowledge alarms.

Faults

Details fault conditions that cause the pump to shut off and their resolutions.

Primary motor

Troubleshoots issues related to the primary motor, such as overheating or failure to start.

Intensifier

Focuses on troubleshooting leaks within the intensifier system.

Overstroke

Addresses overstroke alarms, their causes, and diagnostic steps.

Hydraulic fluid

Troubleshoots issues related to the hydraulic fluid, such as the intensifier not stroking.

Temperature

Discusses issues related to hydraulic fluid temperature and cooling systems.

Water

Covers troubleshooting for low-pressure water supply issues.

High-pressure water

Addresses problems with achieving target water pressure and high-pressure leaks.

Leaks

Covers various types of leaks within the system and their solutions.

Specifications

Environmental conditions

Lists ambient temperature, humidity, and storage conditions.

Hydraulic fluid

Specifies the type, capacity, and operating parameters for hydraulic fluid.

Echion 15

Provides dimensions, weights, electrical, and water specifications for the Echion 15 model.

Echion 30

Lists dimensions, weights, electrical, and water specs for the Echion 30 model.

Echion 50

Details dimensions, weights, electrical, and water specs for the Echion 50 model.

Torque values

Provides torque specifications for fasteners like end cap nuts and flange bolts.

Fittings

Lists torque values for various high-pressure water fittings.

Installation

Safety

Essential safety warnings and guidelines to follow during installation.

Buyer responsibilities

Lists obligations of the buyer related to equipment installation and site preparation.

Requirements

Covers location, cooling, and hydraulic fluid requirements for installation.

Receive and unpack the equipment

Provides instructions for inspecting and verifying the delivered equipment.

Install the pump

Guides the placement and initial setup of the pump.

Connect the utilities to the pump

Explains how to connect compressed air, water, and cooling lines to the pump.

Connect the water and the air

Details the connections for cutting water, waste water, and compressed air.

Connect the electrical power

Covers the procedure for connecting the pump to the electrical power supply.

Do the first start

Provides the procedure for the initial startup of the pump.

Flush the pump and the high-pressure tubing

Describes how to flush the system to remove debris from new tubing.

Operator interface: Adjustment screens

Explains how to use adjustment screens to configure system settings.

Start Procedure Timers

Details how to adjust timers for the pump's startup sequence.

Pressure Adjustments

Guides users on adjusting maximum pressure and pressure increments.

Intensifier Control

Explains how to enable/disable the intensifier and set overstroke percentage.

Touchscreen maps

Primary operation screen

Visual guide to the primary operation screen and its various states.

Adjustment screens

Maps showing navigation through different system adjustment screens.

Maintenance screens

Visual guide to accessing maintenance-related screens on the operator interface.

Technical drawings

Hydraulic and water system drawing

Schematic diagram illustrating the hydraulic and water systems.

Hypertherm Echion Specifications

General IconGeneral
BrandHypertherm
ModelEchion
CategoryWater Pump
LanguageEnglish