Installation
7
Echion Operator Manual 810770 159
Installation
Check the hydraulic fluid
Look at the sight gauge to check the hydraulic fluid level. Add hydraulic fluid, if necessary. Refer to
Add hydraulic fluid on page 85 for instructions.
Do the first start
Use this procedure:
at installation.
when putting the equipment into operation after storage or shipping.
after maintenance or repairs are done on the intensifier, the high-pressure water system, or
the low-pressure water system.
CAUTION
Make sure that hydraulic fluid is available during installation and for the first start.
CAUTION
If a water line, a fitting, or a valve could be frozen, do not operate the pump. Thaw the equipment
until water moves easily through the system.
Examine the parts for damage. Replace parts, if necessary.
CAUTION
This procedure could cause damage to the orifice.
Do not do the first start with a diamond orifice installed. Hypertherm recommends using a ruby
orifice during the first40 hours of operation.