Specifications
6
Echion Operator Manual 810770 141
Specifications
Orifices
US Customary (inches)
Stroke rate
The maximum intensifier stroke rate is calculated using the motor wattage and the size of the
hydraulic pump.
Number of orifices Echion 15 Echion 30 Echion50
10.0070.0110.014
2 0.005 0.007 0.010
3 0.004 0.006 0.008
4 0.005 0.007
5 0.004 0.006
6 0.005
Echion pump model
Maximum
strokes/minute
Echion 15 40 Default overstroke percentage = 5%
Echion 30 79 Maximum overstroke percentage = 20%
Echion 50 107