EasyManuals Logo
Home>Hypertherm>Water Pump>Echion

Hypertherm Echion User Manual

Hypertherm Echion
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #140 background imageLoading...
Page #140 background image
Specifications
6
140 810770 Operator Manual Echion
Specifications
Echion 50
Dimensions and weights
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are measured at
shipment. Operating weight is for an unpackaged pump with hydraulic fluid.
Electrical
Water
Length 135 cm (53 in.) Shipping weight 1,000 kg (2,200 lb)
Width 109 cm (43 in.) Operating weight 925 kg (2,050 lb)
Height 101 cm (40 in.)
37.3 kW, 50 hp 50 Hz 60 Hz
Voltage 400 V 208 V to 230 V 460 V
Full-load current 74 A 136 A to 124 A 62 A
Primary circuit breaker rating 100 A200 A100 A
Minimum Maximum
Cutting water in
Flow 7.6 L/minute (2 gallon/minute)
Pressure 2.8 bar (280 kPa / 40 psi) 7.6 bar (760 kPa / 110 psi)
Cutting water out
Flow 3.8 L/minute (1 gallon/minute)
Pressure 345 bar (34,500 kPa / 5,000 psi) 4,140 bar (414,000 kPa / 60,000 psi)
Cut-pressure
factory setpoint
4,140 bar (414,000 kPa / 60,000 psi)
Pierce-pressure
factory setpoint
1,380 bar (138,000 kPa / 20,000 psi)
Cooling in and Cooling out
Flow 11.4 L/minute (3 gallons/minute)
Pressure 2.8 bar (280 kPa / 40 psi) 7.6 bar (760 kPa / 110 psi)