Preventive maintenance
3
Echion Operator Manual 810770 93
Preventive maintenance
Prepare for storage
Use this procedure to prepare the system for storage. Clearing the water lines prevents freezing,
which can cause damage to the pump.
Refer to Connect the water and the air on page 157 for information about the connections.
Parts, tools, and materials
WARNING
High-pressure water can cause eye injuries. Wear approved eye protection when operating or
doing work near this equipment.
Do not stand over components such as tubes or valves while drying the system.
All low-pressure water connections use push-to-connect fittings.
4
3
2
1
6
5
7
Cutting water in
Boost pump
Inlet water solenoid (for systems
without a boost pump)
Waste water out
Compressed air
Cutting water out
7
4
Water-cooled system
Cooling in
Cooling out
5
6
1/8-inch male to 1/2-inch male adapter
(compressed air to cutting water in)
1/8-inch male to 1-inch male adapter
(compressed air to cooling in)
7/16-inch open-ended wrench
1-1/16-inch open-ended wrench
Filter wrench (included in the standard tool kit)
Water-cooled system
1-inch open-ended wrench
1-3/16-inch open-ended wrench