Operation
2
38 810770 Operator Manual Echion
Operation
Safety
About the controls
Operation panel
WARNING
Read and understand all of the safety guidelines in this manual.
Refer to Safety on page 21 before operating, doing maintenance on, repairing, and installing
your pump.
1
2
3
4
1 Controls button
Push this button to turn
ON the control circuit in
the pump. The button lights when the control
circuit is on.
2 Local/Remote key switch
When the key switch is in the Local
position, use the operator interface to
operate the pump.
When the key switch is in the Remote
position, use the remote source, such as a
computer numerical control (CNC)
operator console, to controls the pump.
Most functions on the operator interface are not
available when the key switch is in the Remote
position.
3 EMERGENCY STOP button
Push this button to turn off the control circuit.
Refer to Emergency stop on page 51.
4 Remote indicator light
When the key switch is in the Remote position, this
indicator light is on.