EasyManua.ls Logo

Hypertherm HyPrecision Predictive P-15 - Page 211

Hypertherm HyPrecision Predictive P-15
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HyPrecision Predictive waterjet pump Operator Manual 810120 211
9 – Installation
Installation
4. Turn ON the pump in cooling mode momentarily. Then touch the STOP symbol. The intent is to make the motor
shaft turn so that you can see the direction it moves without starting the pump.
5. Make sure that the primary motor turns in the direction shown by the rotation arrow.
If the pump motor turns in the wrong direction:
a. Disconnect the electrical power to the pump.
b. In the electrical enclosure, interchange 2 cables on the top of the primary circuit breaker.
6. Make sure that the primary motor turns in the direction shown by the rotation arrow.
7. Install the shaft access cover.
1
2
1
COOLING ON
2
STOP

Table of Contents