MAX200 Product Configuration Manual
1-2
SPECIFICATIONS
Dimensions:
Width ............................................................28-1/4" (71 cm)
Height ...........................................................35-1/2" (90 cm) w/o casters; 40-3/4" (104 cm) -CE
43" (109 cm) w/casters; 48-1/4" (122 cm) -CE
Depth............................................................41-1/4" (104 cm) w/o handle
50" (127 cm) w/handle
Weight ..........................................................780 pounds (351 kg); 800 pounds (363 kg) -CE
Cooling .........................................................Forced Air (Class F)
Torch Coolant Tank Capacity .......................2.9 gallons (11 liters)
Torch Coolant Requirements and
Coolant Safety Data .....................................See Appendix section of instruction manual
Gas Requirements:
Gas Type/Quality..........................................Air (compressed)/clean, dry, oil-free
Oxygen (O
2
)/99.5% (liquid)
Nitrogen (N
2
)/99.995% (liquid)
Carbon Dioxide (CO
2
)/99.5% (compressed or
liquid)
Argon/Hydrogen (H35 = 35% Hydrogen/65%
Argon)
Plasma Gases ..............................................Air, O
2
, N
2
, H35
Shield Gases ................................................Air, CO
2
, N
2
Plasma Gas Flow .........................................66 scfh (Air), 60 scfh (N
2
), 70 scfh (H35),
72 scfh (O
2
)
Shield Gas Flow ...........................................220 scfh (CO
2
), 280 scfh (Air), 290 scfh (N
2
)
Plasma Gas Inlet Pressure ..........................90/120 psi (6.2/8.3 bar) (flowing)
Shield Gas Inlet Pressure ............................90 psi (6.2 bar) (flowing)
Plasma Gas Pressure (Test/Run).................See
Cut Charts
in Operation section of IM87
(#800870) or IM98 (#800980)
Shield Gas Pressure ....................................70 psi (4.8 bar)
PAC200T (90° & 65°) Cutting/PAC200E (65°) Gouging/MAX200 Rev 1 (90°) Hand
Torches
Maximum cutting thickness ..........................2 inches (50 mm)
Maximum current at 100% duty cycle ..........200 amps
Plasma Gas Flow .........................................66 scfh (Air), 60 scfh (N
2
), 70 scfh (H35), 72 scfh
(O
2
)
Shield Gas Flow ...........................................220 scfh (CO
2
), 280 scfh (Air), 290 scfh (N
2
)
Water Coolant Flow Rate .............................0.8 gpm (3.0 l/min)
Weight ..........................................................3 lbs (1.4 kg - MAX200 Rev 1 90°) 2-1/2 lbs.
(1.1 kg - PAC200T/E)