General Troubleshooting
If the torch does not want to start check the following:
PlasmaCAM “Cutting” is on.
The LED will be green in the Auto portion of the control panel
Front panel of the Hypertherm power supply for fault indications
Yellow Torch LED -- Check the torch head cup for tightness
Yellow Temp LED -- power supply is too hot
Gas Pressure LED
If flashing yellow check the air pressure
Should be above 60 psi MINIMUM. Remember the 2 LEDs on
panel indicate pressure range
Check for proper grounding of the table AND the stock