POWERMAX1000/1250/1650 PA IGBT REPLACEMENT
Field Service Bulletin 3
Powermax1650
Gate-drive wire
Powerboard
PA IGBT
Heat sink
PA IGBT
M6 machine screws
M5 machine screws
Red wire
Black wire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 1650 and is the answer not in the manual?

Hypertherm Powermax 1650 Specifications

General IconGeneral
Gas SupplyAir or Nitrogen
Recommended Gas Flow Rate200-300 L/min
Air Pressure Requirement6-8 bar
Air Flow Requirement300 L/min
Dimensions800 x 600 x 1200 mm