Nicholas CamposJul 26, 2025
What to do if the spot weld is not visible while gouging with Hypertherm Powermax45 XP?
- CChristopher ReidJul 26, 2025
To improve visibility of the spot weld during gouging: * Stretch the arc to approximately 10 – 11 mm (3/8 – 1/2 inch). * Ensure that the Precision gouging consumables are installed. * Make sure the output current is not set above 25 A.