1313
Troubleshooting
Phenomena Analysis Solution
The repeater cannot be
powered on.
a. Power cord is not connected or is not securely connected
to the outlet.
b. Power cord fuse is damaged.
a. Properly connect the power cord and ensure
secure connection.
b. Check if the fuse has blown. If yes, replace
it with a new one.
Group members cannot talk
to each other, or the repeater
cannot communicate with a
subscriber radio.
a. TX/RX frequency of the repeater is inconsistent with that of
portable/mobile terminals.
b. Failed to repeat useful signal due to strong interference
signal.
c. The group member is out of the coverage of the repeater.
a. Re-set frequencies.
b. If you cannot remove or bypass the
interference source, change to operate at
other frequencies.
c. Go within the coverage of the repeater.
Group members cannot talk
to each other, even though
RX indication is given.
a. Your ID is inconsistent with that of other group members.
b. Inconsistent CTCSS/CDCSS.
a. Set your ID to the same as that of other
members.
b. Re-set CTCSS/CDCSS.
Short communication range
or poor audio
a. Leakage of signal energy due to damaged connection
cable.
b. Loose connection between the antenna connector and the
cable, or loss of connection
c. Invisible damage of cable.
d. Duplexer is not properly set (if the duplexer is mounted).
a. Replace the cable with a new one if
necessary.
b. Secure or replace the cable.
c. Replace the cable with a new one.
d. Contact the manufacturer or your dealer to
re-set the duplexer.
If the above solutions can not x your problems, or you may have some other queries, please contact us or your local dealer for more technical