The display will show the option “WATER FILTER”. You have to select the number of liters
of water for the “WATER-SOFTENER“ regeneration/replacement alarm. When the number of
liters selected arrive to the number of this option, the alarm advice of the water filter
regeneration/replacement.
Press the to select the amount.
WARNING: If you leave this amount to zero “0”, you have this option “DISABLE” and NO
ALARM will advise for the water softener.
Finally, press
MENU
button to finish all the TECHNICAL’S MENU options.
1.9.- ALARMS AND WARNING SIGNALS (optional)
Time-out alarm
Filling up
A. BOILER FILL UP EXCEEDING TIME.
After exceeding the time of the “Filling UP-T-out” time option, the display will show:
At the same time all the LEDS of the dosing selections will wink.
In order to cancel this alarm, you have to TURN OFF (position 0) the main switch, and
following TURN ON (position 1).
alarm
Boiler temp
B. EXCEEDING BOILER TEMPERATURE.
(NO available for the IBERITAL Model with pressure boiler control by “Pressure Switch”).
The display will show the temperature alarm of the boiler when this temperature will pass over
140ºC during more than 5 seconds.
This alarm will disappear when the boiler temperature will come back to normal value.