IBERITAL DE RECAMBIOS, S.A.
T. probe / unconnect
C. TEMPERATURE PROBE CUT-OFF.
When this probe notices a temperature of 0ºC during 5 seconds, the LEDS of the dosing buttons
will wink and the display will show:
This alarm will disappear when the boiler temperature will come back to normal value.
alarm
Flow meter GR x
D. FAILURE IN THE VOLUMETRIC COUNTER (FLOW METER)
When the volumetric counter is not dosing well or it is not receiving the proper signals during 5
seconds, the LED of the dosing button will wink and the display will show:
Change water filt
xxxxxxx
E. WATER FILTER CHANGE /REGENERATION
After exceeding the liters of water selected in the “WATER FILTER” option of the
TECHNICAL’S MENU, the display will show:
In order to cancel this alarm, press the “2 long coffees” and “2 short coffees (espressos)” at the
same time in the GROUP Nº 1 (left hand group).
MANUAL NEW IBERITAL INGLES Página 22 de 30