Path/Filename [<home dir>/config.txt]: config-switch0.txt
Section (all|chassis|switch [all]): all
Password:
Upload complete
switch: admin>
4. Record the WWN value: Enter wwn, and then copy the command output into a file named
config-miscinfo.txt.
switch:admin> wwn
10:00:00:60:69:00:00:0a
5. Enter ipAddrShow, and then copy the command output into the config-miscinfo.txt file.
switch:admin> ipaddrshow
SWITCH
Ethernet IP Address: 14.25.60.14
Ethernet Subnetmask: 255.55.0.0
Gateway IP Address: 14.25.43.1
DHCP: Off
6. Display and record the manufacturer serial numbers.
Enter chassisShow, and then copy the command output into the config-miscinfo.txt file.
"Factory Serial Num" and "Serial Num" are listed under "Chassis/WWN Unit 1" and "Chassis/WWN
Unit 2". If the current WWN cards are the original cards, the factory serial number listed is the same
as the chassis serial number.
CHASSIS/WWN Unit: 1
Header Version: 2
Power Usage: -288W
Factory Part Num: 40-1000864-11
Factory Serial Num: CWA2551K00V
Manufacture: Day: 1 Month: 11 Year: 2014
Update: Day: 29 Month: 6 Year: 2017
Time Alive: 774 days
Time Awake: 17 days
ID: IBM0000CA
Part Num: 0024980000R42
Serial Num: 10450TC
7. Create a SAN "profile" by entering and recording the information provided by the following
commands:
v nsShow
v nsAllShow
v switchShow
v fabricShow
Copy the command output into a text file named "SANbefor.txt." After the device is restored to the
fabric, this information can be used to verify that no unintentional changes have occurred to the
fabric.
switch:admin> nsshow
Enter Pid COS PortName NodeName TTL
<output truncated>
switch:admin> nsallshow
12 Nx_Ports in the Fabric
<output truncated>
switch:admin> switchshow
switchName: switch
<output truncated>
switch:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
switch:admin>
8. Enter licenseShow, and then copy the command output into a text file named "licenseshow.txt."
74 SAN128B-6 Installation, Service, and User Guide