Table 47. Ethernet connections available with the file modules
Item Port
IP address is assigned
by InitTool Use
1 Ethernet port 7 Connect to a switch for
public file access
2 Ethernet port 8 Connect to a switch for
public file access
3 Ethernet port 9 Connect to a switch for
public file access
4 Ethernet port 10 Connect to a switch for
public file access
5 Ethernet port 1 From the internal IP
address range
Connect to the other file
module
6 Ethernet port 2 From the internal IP
address range
Connect to the other file
module
7 Ethernet port 3 File module service and
system management IP
address
Connect to a switch for
public file access and
system management
8 Ethernet port 4 Connect to a switch for
public file access
9 Ethernet port 5 (10 Gbps
optical )
Connect to a switch for
public file access and
optional system
management
10 Ethernet port 6 (10 Gbps
optical )
Connect to a switch for
public file access
1
2
3
4
5
6
1
2
3
4
5
6
5
10
7
8
9
ifs00066
1
2
3
4
6
Figure 54. File module Ethernet connections.
Chapter 5. Performing the hardware installation 93