T is the technician port. Never connect a technician port to a network switch.
Table 46. Ethernet connections available with the Storwize V7000 Gen2 control enclosure
Item Port Purpose
IP address is
assigned by
InitTool Use
1 (Figure 53) Built-in
Ethernet port 1
1 Gbps external
network
connection
Yes Management
and service
port for each
canister;
optional iSCSI.
(The Storwize
V7000 control
enclosure must
be able to
communicate
over the
network with
the file
modules.)
2 (Figure 53) Built-in
Ethernet port 2
1 Gbps external
network
connection
No Optional
management
and service
port; optional
iSCSI
3 (Figure 53) Built-in
Ethernet port 3
1 Gbps external
network
connection
No Optional
management
and service
port; optional
iSCSI
4 (Figure 53) Ethernet port 4 10 GbE external
network
connection
No Optional iSCSI
5 (Figure 53) Ethernet port 5 10 GbE external
network
connection
No Optional iSCSI
6 (Figure 53) Ethernet port 6 10 GbE external
network
connection
No Optional iSCSI
7 (Figure 53) Ethernet port 7 10 GbE external
network
connection
No Optional iSCSI
fab10041
32121 3
1 2
5
6
7
4
3 T
Figure 53. Ethernet ports when an optional 10 Gbps Ethernet interface card is present in PCI
slot 3
92 IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720