EasyManuals Logo

IBM Storwize V7000 Unified User Manual

IBM Storwize V7000 Unified
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Note: You cannot use VLAN-based subnets to initialize the system management
network. To set the file module management IP address, file module 1 and 2 IP
addresses, subnet mask, and gateway address, you must provide non-VLAN based
network information. Also, all IP addresses entered must be on the same subnet as
the Storwize V7000 system IP address. After the system is configured, use the
chnwmgt command to change the Storwize V7000 Unified network settings to
switch to a VLAN-based subnet. This recreates the network with a VLAN-based
subnet. You must also use the chsystem -consoleip command to show the
Storwize V7000 the new management IP address.
Note: The example addresses in this table match the ones given on Figure 23 on
page 53.
Table 36. The following IP address information is required before initializing your system. Fill
in all the information needed in the Value column before proceeding with this installation.
Field Value Notes
Storwize V7000 Primary
system IP address
Primary IP address for the
Storwize V7000 system (such
as 123.123.123.20)
Storwize V7000 Secondary
system IP address
Optional Secondary IP
address for the Storwize
V7000 system (such as
123.123.123.19)
Storwize V7000 node canister
1 service IP address
Service IP address of canister
1 in the control enclosure
(such as 123.123.123.20) This
is not set by the USB
initialize or the management
GUI.
Network subnet mask The Subnet used for
management communications
(such as 255.255.255.0)
Gateway address Gateway IP address for the
management subnet
Internal IP address range The internal IP addresses are
for internal communication
among the Storwize V7000
Unified components for
management and
maintenance. Select one of
the IP address ranges listed
below. The range you select
must not conflict with the IP
addresses used for your
Ethernet connections to the
management nodes or
interface nodes. The available
IP address ranges are:
1. 172.31.8.*
2. 192.168.8.*
3. 10.254.8.*
54 IBM Storwize V7000 Unified: Adding Storwize V7000 File Modules to an existing Storwize V7000 system 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals