Table 27. Informational events (continued)
Event ID
Notification
type Description
984509 I The component firmware update paused to allow the
battery charging to finish.
984511 I The update for the component firmware paused
because the system was put into maintenance mode.
984512 I A component firmware update is needed but is
prevented from running.
985001 I The Metro Mirror or Global Mirror background copy
is complete.
985002 I The Metro Mirror or Global Mirror is ready to restart.
985003 W Unable to find path to disk in the remote cluster
(system) within the timeout period.
986001 W The thin-provisioned volume copy data in a node is
pinned.
986002 I All thin-provisioned volume copy data in a node is
unpinned.
986010 I The thin-provisioned volume copy import has failed
and the new volume is offline; either upgrade the
Storwize V7000 software to the required version or
delete the volume.
986011 I The thin-provisioned volume copy import is
successful.
986020 W A thin-provisioned volume copy space warning has
occurred.
986030 I A thin-provisioned volume copy repair has started.
986031 I A thin-provisioned volume copy repair is successful.
986032 I A thin-provisioned volume copy validation is started.
986033 I A thin-provisioned volume copy validation is
successful.
986034 I The import of the compressed-virtual volume copy
was successful.
986035 W A compressed-virtual volume copy space warning
has occurred.
986036 I A compressed-virtual volume copy repair has started.
986037 I A compressed-virtual volume copy repair is
successful.
986038 I A compressed-virtual volume copy has too many bad
blocks.
986201 I A medium error has been repaired for the mirrored
copy.
986203 W A mirror copy repair, using the validate option
cannot complete.
986204 I A mirror disk repair is complete and no differences
are found.
986205 I A mirror disk repair is complete and the differences
are resolved.
Chapter 9. Event reporting 127

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
BrandIBM
ModelStorwize V7000
CategoryStorage
LanguageEnglish

Related product manuals