Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
029002 E The system failed to create a bad block because MDisk
already has the maximum number of allowed bad
blocks.
1226
029003 E The system failed to create a bad block because the
clustered system already has the maximum number of
allowed bad blocks.
1225
030000 W The trigger prepare command has failed because of a
cache flush failure.
1900
030010 W The mapping is stopped because of the error that is
indicated in the data.
1910
030020 W The mapping is stopped because of a clustered system or
complete I/O group failure, and the current state of the
relationship could not be recovered.
1895
045001 E One or more power supply unit fans have failed. 1124
045002 E A fan is operating outside the expected range. 1126
045003 E There was a fan status communications failure. 1126
045004 E The power supply unit is not installed. 1128
045005 W The power supply unit has indicated an input power
failure.
1138
045006 E The power supply unity has indicated an output failure. 1126
045007 E The power supply unit has failed. 1124
045008 E There is no communication with the power supply unit. 1148
045009 E The model type for this enclosure is not valid. 1124
045010 E The power supply unit type is unknown to this product. 1124
045011 E The power supply unit serial number is not valid. 1124
045012 W The canister temperature is at the warning level. 1098
045013 W The canister temperature is at the critical level. 1095
045014 E The SAS cable was excluded because of a missing device. 1260
045015 E A SAS cable was excluded because too many change
events were caused.
1260
045016 E A SAS cable was excluded. 1255
045017 E A SAS cable is operating at a reduced speed. 1260
045018 E A SAS cable was excluded because frames were dropped. 1260
045019 E A SAS cable was excluded because the enclosure
discovery timed out.
1260
045020 W A SAS cable is not present. 1265
045021 E A canister was removed from the system. 1036
045022 E A canister has been in a degraded state for too long and
cannot be recovered.
1034
045023 E A canister is encountering communication problems. 1038
045024 E The canister VPD is not valid. 1032
045025 E The canister has experienced too many resets. 1032
045026 E The drive slot is causing the network to be unstable. 1686
Chapter 9. Event reporting 133