Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
045027 E The drive slot is not running at 6 Gbps 1686
045028 E The drive slot is dropping frames. 1686
045029 E The drive is visible through only one SAS port. 1686
045031 E The drive power control is not functional. 1008
045033 E The drive slot contains a device that is not responding to
queries.
1685
045034 E The managed enclosure is not visible from any node
canisters.
1042
045035 E The electronics in the enclosure has failed. 1694
045036 E The electronics in the enclosure has experienced a critical
failure.
1008
045037 E The SAS network has too many errors. 1048
045038 E The SAS network has too many errors. 1048
045040 W The firmware update for the enclosure component has
failed.
3015
045041 W More than one initiator port was detected on the same
strand.
1005
045042 W The order of the enclosures is different on each strand. 1005
045044 W Multiple canisters are connected to a single canister port. 1005
045045 W Canister 1 is connected to canister 2. 1005
045046 W An enclosure is connected to more than one I/O group. 1005
045047 W A managed enclosure is connected to the wrong I/O
group.
1005
045048 W An enclosure is connected to more than one chain. 1005
045049 W Too many canisters are connected to a strand. 1005
045050 W The canister is connected to the wrong port. 1005
045051 E A SAS cable is excluded because of single port active
drives.
1260
045052 W More than one canister was detected at the same hop
count.
1005
045053 E The node location is not able to be detected. 1031
045054 E An enclosure display cannot be updated. 1694
045055 E There is an enclosure battery fault. 1118
045056 E An enclosure battery is missing. 1112
045057 E An enclosure battery is nearing end of life. 1114
045058 E An enclosure battery is at end of life. 1113
045062 W An enclosure battery conditioning is required but not
possible.
1131
045063 E There was an enclosure battery communications error. 1116
045064 W A SAS port is active, but no enclosures can be detected. 1005
045065 E There is a connectivity problem between a canister and
an enclosure.
1036
134 Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide