Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
062001 W Unable to mirror medium error during volume copy
synchronization
1950
062002 W The mirrored volume is offline because the data cannot
be synchronized.
1870
062003 W The repair process for the mirrored disk has stopped
because there is a difference between the copies.
1600
070000 E Unrecognized node error. 1083
070510 E Detected memory size does not match the expected
memory size.
1022
070517 E The WWNN that is stored on the service controller and
the WWNN that is stored on the drive do not match.
1192
070521 E Unable to detect any Fibre Channel adapter. 1016
070522 E The system board processor has failed. 1020
070523 W The internal disk file system of the node is damaged. 1187
070524 E Unable to update BIOS settings. 1027
070525 E Unable to update the service processor firmware for the
system board.
1020
070528 W The ambient temperature is too high while the system is
starting.
1182
070550 E Cannot form clustered system due to lack of resources. 1192
070556 E Duplicate WWNN detected on the SAN. 1192
070558 E A node is unable to communicate with other nodes. 1192
070562 E The node hardware does not meet minimum
requirements.
1183
070564 E Too many software failures. 1188
070574 E The node software is damaged. 1187
070576 E The clustered system data cannot be read. 1030
070578 E The clustered system data was not saved when power
was lost.
1194
070580 E Unable to read the service controller ID. 1044
070690 W Node held in service state. 1189
071820 W Node canister has the incorrect model for the enclosure. 3020
071840 W Detected hardware is not a valid configuration. 1198
071841 W Detected hardware needs activation. 1199
072900 E There was a PCIe link failure between canisters. 1006
072901 E The PCIe link is degraded between canisters. 1052
072911 E The PCIe link for the CPU is degraded. 1034
073003 E The Fibre Channel ports are not operational. 1060
073005 E Clustered system path failure. 1550
073006 W The SAN is not correctly zoned. As a result, more than
512 ports on the SAN have logged into one Storwize
V7000 port.
1800