Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
073007 W There are fewer Fibre Channel ports operational than are
configured.
1061
073305 W One or more Fibre Channel ports are running at a speed
that is lower than the last saved speed.
1065
073310 E A duplicate Fibre Channel frame has been detected,
which indicates that there is an issue with the Fibre
Channel fabric. Other Fibre Channel errors might also be
generated.
1203
073501 E Incorrect canister position. 1192
073502 E No enclosure identity; cannot get status from partner. 1192
073503 E Incorrect enclosure type. 1192
073504 E No enclosure identity and partner does match. 1192
073505 E No enclosure identity and partner does not match. 1192
073506 E No enclosure identity and no state on partner. 1192
073507 E No enclosure identity and no node state. 1192
073508 W Clustered system identity is different on the enclosure
and the node.
1023
073509 E Cannot read enclosure identity. 1036
073510 E Detected memory size does not match the expected
memory size.
1032
073512 E Enclosure VPD is inconsistent 1008
073522 E The system board service processor has failed. 1034
073523 W The internal disk file system of the node is damaged. 1187
073525 E Unable to update the service processor firmware of the
system board.
1034
073528 E Ambient temperature is too high during system startup. 1098
073535 E The internal PCIe switch of the node canister failed. 1034
073550 E Cannot form clustered system due to lack of resources. 1192
073556 E Duplicate WWNN detected on the SAN. 1133
073562 E The node hardware does not meet the minimum
requirements.
1034
073565 E The internal drive of the node is failing. 1032
073573 E The node software is inconsistent. 1187
073574 E The clustered system data cannot be read. 1187
073578 E The clustered system data was not saved when power
was lost.
1194
073651 E The canister battery is missing. 1153
073652 E The canister battery has failed. 1154
073653 E The canister battery’s temperature is too low. 1156
073654 E The canister battery’s temperature is too high 1157
073655 E The canister battery communications fault. 1158
073656 E The canister battery has insufficient charge. 1184
Chapter 9. Event reporting 137

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
ModelStorwize V7000
Storage TypeHybrid Flash Array
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive TypesSSD, SAS
Host Interface8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI, 12 Gbps SAS
Maximum Cache32GB
Operating System SupportIBM AIX, Linux, Windows, VMware
Data Reduction FeaturesReal-time Compression
Management SoftwareIBM Spectrum Virtualize