Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
073700 E FC adapter missing. 1045
073701 E FC adapter failed. 1046
073702 E FC adapter PCI error. 1046
073703 E FC adapter degraded. 1045
073704 W Fewer Fibre Channel ports operational. 1061
073705 W Fewer Fibre Channel IO ports operational. 1450
073710 E SAS adapter missing. 1045
073711 E SAS adapter failed. 1046
073712 E SAS adapter PCI error. 1046
073713 E SAS adapter degraded. 1046
073720 E Ethernet adapter missing. 1045
073721 E Ethernet adapter failed. 1046
073722 E Ethernet adapter PCI error. 1046
073723 E Ethernet adapter degraded. 1046
073724 W Fewer Ethernet ports operational. 1401
073730 E Bus adapter missing. 1032
073731 E Bus adapter failed. 1032
073732 E Bus adapter PCI error. 1032
073733 E Bus adapter degraded. 1032
073734 W Inter-canister PCIe link failure. 1006
073768 W Ambient temperature warning. 1094
073769 W CPU temperature warning. 1093
073840 E Detected hardware is not a valid configuration. 1198
073841 E Detected hardware needs activation. 1199
073860 W Fabric too large. 1800
074001 W Unable to determine the vital product data (VPD) for an
FRU. This is probably because a new FRU has been
installed and the software does not recognize that FRU.
The clustered system continues to operate; however, you
must upgrade the software to fix this warning.
2040
074002 E The node warm started after a software error. 2030
074003 W A connection to a configured remote system has been
lost because of a connectivity problem.
1715
074004 W A connection to a configured remote system has been
lost because of too many minor errors.
1716
076001 E The internal disk for a node has failed. 1030
076002 E The hard disk is full and cannot capture any more
output.
2030
076401 E One of the two power supply units in the node has
failed.
1096
076402 E One of the two power supply units in the node cannot
be detected.
1096
138 Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
ModelStorwize V7000
Storage TypeHybrid Flash Array
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive TypesSSD, SAS
Host Interface8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI, 12 Gbps SAS
Maximum Cache32GB
Operating System SupportIBM AIX, Linux, Windows, VMware
Data Reduction FeaturesReal-time Compression
Management SoftwareIBM Spectrum Virtualize