Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
073700 E FC adapter missing. 1045
073701 E FC adapter failed. 1046
073702 E FC adapter PCI error. 1046
073703 E FC adapter degraded. 1045
073704 W Fewer Fibre Channel ports operational. 1061
073705 W Fewer Fibre Channel IO ports operational. 1450
073710 E SAS adapter missing. 1045
073711 E SAS adapter failed. 1046
073712 E SAS adapter PCI error. 1046
073713 E SAS adapter degraded. 1046
073720 E Ethernet adapter missing. 1045
073721 E Ethernet adapter failed. 1046
073722 E Ethernet adapter PCI error. 1046
073723 E Ethernet adapter degraded. 1046
073724 W Fewer Ethernet ports operational. 1401
073730 E Bus adapter missing. 1032
073731 E Bus adapter failed. 1032
073732 E Bus adapter PCI error. 1032
073733 E Bus adapter degraded. 1032
073734 W Inter-canister PCIe link failure. 1006
073768 W Ambient temperature warning. 1094
073769 W CPU temperature warning. 1093
073840 E Detected hardware is not a valid configuration. 1198
073841 E Detected hardware needs activation. 1199
073860 W Fabric too large. 1800
074001 W Unable to determine the vital product data (VPD) for an
FRU. This is probably because a new FRU has been
installed and the software does not recognize that FRU.
The clustered system continues to operate; however, you
must upgrade the software to fix this warning.
2040
074002 E The node warm started after a software error. 2030
074003 W A connection to a configured remote system has been
lost because of a connectivity problem.
1715
074004 W A connection to a configured remote system has been
lost because of too many minor errors.
1716
076001 E The internal disk for a node has failed. 1030
076002 E The hard disk is full and cannot capture any more
output.
2030
076401 E One of the two power supply units in the node has
failed.
1096
076402 E One of the two power supply units in the node cannot
be detected.
1096
138 Storwize V7000: Troubleshooting, Recovery, and Maintenance Guide