EasyManuals Logo

IBM System x3100 M4 Type 2582 Problem Determination And Service Guide

IBM System x3100 M4 Type 2582
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
Table 7. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number Component Test State Description Action
215-903-xxx Optical Drive
v Verify Media
Installed
v Read/ Write
Test
v Self-Test
Messages and
actions apply to
all three tests.
Aborted Could not access
the drive.
1. Insert a CD/DVD into the drive or try
a new media, and wait for 15
seconds.
2. Run the test again.
3. Check the drive cabling at both ends
for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.
4. Run the test again.
5. Make sure that the DSA code is at
the latest level. For more information
and to download the utilities, go to
http://www.ibm.com/systems/support/
supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-DSA.
6. Run the test again.
7. For additional troubleshooting
information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
8. Run the test again.
9. Replace the CD/DVD drive.
10. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
217-000-000 SAS/SATA
Hard Drive
Disk Drive Test Pass The test passed. No action; information only.
217-800-000 SAS/SATA
Hard Drive
Disk Drive Test Aborted The test was
cancelled.
1. Reseat all hard disk drive backplane
connections at both ends.
2. Reseat the all drives.
3. Run the test again.
4. Make sure that the firmware is at the
latest level.
5. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 3. Diagnostics
137

Table of Contents

Other manuals for IBM System x3100 M4 Type 2582

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 Type 2582 and is the answer not in the manual?

IBM System x3100 M4 Type 2582 Specifications

General IconGeneral
Form FactorTower
ChipsetIntel C202
Memory Slots4 DIMM slots
ProcessorIntel Pentium
MemoryUp to 32GB DDR3
StorageUp to 4 x 3.5"
Power Supply350W
Network InterfaceIntegrated Gigabit Ethernet
RAID SupportRAID 0, 1
Expansion Slots1 PCI
USB Ports6 x USB 2.0 (2 front, 4 rear)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server

Related product manuals