Table 7. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number Component Test State Description Action
217-900-000 SAS/SATA
Hard Drive
Disk Drive Test Failed The test detected a
failure.
1. Reseat all hard disk drive backplane
connections at both ends.
2. Reseat the all drives.
3. Run the test again.
4. Make sure that the firmware is at the
latest level.
5. Run the test again.
6. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
405-901-xxx Intel Ethernet
Device
Test Control
Registers
Failed A failure was
detected while
testing internal
MAC registers.
1. Make sure that the component
firmware is at the latest level. The
installed firmware level is shown in
the DSA event log in the
Firmware/VPD section for this
component. For more information, see
“Updating the firmware” on page 267.
2. Run the test again.
3. Replace the component that is
causing the error. If the error is
caused by an adapter, replace the
adapter. Check the PCI Information
and Network Settings information in
the DSA event log to determine the
physical location of the failing
component.
4. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
138 IBM System x3100 M4 Type 2582: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3100 M4 Type 2582

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 Type 2582 and is the answer not in the manual?

IBM System x3100 M4 Type 2582 Specifications

General IconGeneral
Form FactorTower
ChipsetIntel C202
Memory Slots4 DIMM slots
ProcessorIntel Pentium
MemoryUp to 32GB DDR3
StorageUp to 4 x 3.5"
Power Supply350W
Network InterfaceIntegrated Gigabit Ethernet
RAID SupportRAID 0, 1
Expansion Slots1 PCI
USB Ports6 x USB 2.0 (2 front, 4 rear)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server