Note: A VRM must be installed when a second microprocessor is installed in
order to power on the server.
a. Open the retaining clips on each end of the VRM connector.
b. Turn the VRM so that the keys align with the connector.
c. Insert the VRM into the connector by aligning the edges of the VRM with
the slots at the end of the VRM connector. Firmly press the VRM straight
down into the connector by applying pressure on both ends of the VRM
simultaneously. The retaining clips snap into the locked position when the
VRM is seated in the connector.
14. Reinstall the air baffle (see “Installing the air baffle” on page 53).
15. Close the power-supply cage (see “Closing the power-supply cage” on page
56).
16. Reinstall the hot-swap power supplies.
17. Reinstall the left-side cover (see “Completing the installation” on page 98).
18. Reconnect the external cables and power cords.
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 98.
Chapter 2. Installing optional devices 97

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3400 M3 Types 7378 and is the answer not in the manual?

IBM System x3400 M3 Types 7378 Specifications

General IconGeneral
BrandIBM
ModelSystem x3400 M3 Types 7378
CategoryServer
LanguageEnglish

Related product manuals