EasyManua.ls Logo

IBM System x3550 Type 7978 - Page 91

IBM System x3550 Type 7978
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 89 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
180-xxx-002 Failed diagnostics LED panel test. Trained service technician only:
1. Disconnect the server power cords and reseat the
operator information panel cable. Restart the
server.
2. Replace the operator information panel.
180-xxx-003 Failed system board LED test. (Trained service technician only) Replace the system
board.
180-xxx-005 Failed SAS backplane LED test. Reseat the following components, one at a time, in
the order shown, restarting the server each time:
1. SAS backplane.
2. SAS backplane cable.
Replace
the following components, one at a time, in
the order shown, restarting the server each time:
1. SAS backplane.
2. SAS backplane cable.
3. (Trained service technician only) System board.
201-xxx-0nn Failed memory test.
Note: n = slot number of failing DIMM.
Replace the following components one at a time, in
the order shown, restarting the server each time:
1. DIMM identified by nn.
2. (Trained service technician only) System board.
201-xxx-n99 Multiple DIMM failure.
Note: n = bank number of failing pair.
1. See the error text to identify the failing DIMMs.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. DIMMs in bank n.
b. (Trained service technician only) System
board.
202-xxx-00n Failed system cache test.
1. Trained service technician only:
a. Reseat microprocessor 1 (if n = 0 or 1) or
microprocessor 2 (if n = 2 or 3).
b. Replace microprocessor 1 (if n = 0 or 1) or
microprocessor 2 (if n = 2 or 3).
c. Replace the system board.
Chapter 2. Diagnostics 73

Table of Contents

Related product manuals